Utax DP 700 Manual de usuario Pagina 1

Busca en linea o descarga Manual de usuario para Procesadores Utax DP 700. Utax DP 700 User manual Manual de usuario

  • Descarga
  • Añadir a mis manuales
  • Imprimir
  • Pagina
    / 34
  • Tabla de contenidos
  • MARCADORES
  • Valorado. / 5. Basado en revisión del cliente
Vista de pagina 0
User Manual
DP700 Digital Readout
New Lathe Feature
see Page 31
Vista de pagina 0
1 2 3 4 5 6 ... 33 34

Indice de contenidos

Pagina 1 - DP700 Digital Readout

User ManualDP700 Digital Readout New Lathe Feature see Page 31

Pagina 2 - Contents

You use the direction setting to match the DP700 to the actual direction of travel of any axis.There are two settings for each axis

Pagina 3 - Specification

Setting Up The UnitError CompensationYour digital readout (DRO) system helps you to improve productivity. It decreases the numberof scrapped parts, as

Pagina 4 - Mounting Options

Setting Up The UnitTypes of Machine ErrorThere are many types of machine error, including pitch, roll, yaw, flatness, straightness, andAbbé error. The

Pagina 5 - Connection Details

Linear Error Compensation SetupThis setting allows you to setup compensation factors for linear errors. There are two methods of entering compensation

Pagina 6 - Display and Keypad

Setting Up The UnitThe scale travel is broken down into as many as 200 user-defined segments, each with theirown correction factor, measured against a

Pagina 7

Setting Up The UnitPlane SetupsetupplaneThis setting enables the user to choose the plane in which certain functions will operate. Theplane consists o

Pagina 8

Setting Up The UnitBeep SetupThis setting enables the user to have the option of an audible tone on pressing any of thekeys on the DP700.There are two

Pagina 9

Setting Up The Unit17Reset SetupThis setting enables the user to reset the DP700 unit back to factory defaults. There are three factory default settin

Pagina 10 - Setting Up The Unit

30100140190Standard FunctionsAbsolute / IncrementalInch and mmThis chapter details the standard functions of the DP700. Press to toggle between

Pagina 11

Zero and Preset an axisThe DP700 has a dedicated key to switch the operation of the axis selection key between zero modeand set mode. The currently se

Pagina 12

2ContentsSpecification Page 3Electrical Page 3Physical Page 3Environment Page 3Accreditation Page 3Disposal Page 3Input and Resolution Page 3Mounting

Pagina 13

Half Function / Centre FindDigifind / Reference FunctionThe DP700 has a dedicated key to half the value inany axis. This is done by initiating the hal

Pagina 14

Sub Datums / MemoryThe DP700 can store up to 200 SDM (Sub-Datum) positions, or machining steps into thememory. Using SDM allows the operator to work t

Pagina 15

Standard FunctionsRS232 (Data Logging) / Data AcquisitionThe DP700 DRO can offer basic serial communications via a dedicated hardware RS232compatible

Pagina 16

Standard FunctionsRS232 SetupHow to navigate to RS232 setup.Until message display shows,funcsLOGMessage display showsLOgbaud115200Note: Relates to bau

Pagina 17

Standard FunctionsRS232 Output Data FormatThe output data from the RS232 is as follows:The current axis data for the axes available on the system are

Pagina 18 - Standard Functions

PCD / Bolt Hole CircleMill FunctionsThe DP700 calculates positions for a series of equally spaced holes around the circumferenceof a circle. The messa

Pagina 19

Line HoleThe DP700 calculates positions for a series of equally spaced holes on a line. The messagedisplay prompts the user for various parameters it

Pagina 20

Arc ContouringThe DP700 calculates positions for rough machining an arc or radius. The message displayprompts the user for various parameters it needs

Pagina 21

Polar Co-ordinatesThe Polar co-ordinate function enables the operator to convert the displayed data from theconventional cartesian co-ordinates (X,Y)

Pagina 22

Lathe FunctionsThis chapter details the Lathe functions of the DP700. Tool OffsetsThe Tool Offset function allows the operator to enter and store offs

Pagina 23

3EU Directive 73/23/EEC (Low Voltage Directive)BS EN 55022:1998 Class BBS EN 55024:1998Input to Power Supply Unit (Supplied)100-240V (47-63Hz)External

Pagina 24

Program ModeDisplay will show toolsteach Display will now show 0.0000.000set tooltool 01Take a skim cut if X axis is selected, or take a face cut if Z

Pagina 25 - Mill Functions

Lathe FunctionsMultiple Tool Datums31This function only applies to units with software version 1.1.0 and above.The Multiple Tool Datum function offers

Pagina 26

Taper FunctionThe taper function shows the angular displacement of the displayed (X,Z) position.How to navigate to Taper function. Until message displ

Pagina 27

Trouble Shooting GuideSymptom SolutionThe display is blank• The DP700 maybe in sleep mode. press any key to exit sleep mode• Check that the power su

Pagina 28

023-81380-UK/2Newall Measurement Systems Ltd.Technology Gateway, Cornwall RoadSouth Wigston, Leicester LE18 4XH United KingdomTel: +44 (0) 116 264 27

Pagina 29 - Lathe Functions

Lathe Mount (Non Adjustable)Adjustable Mount OptionsPanel Mount OptionThis chapter details the various mounting options for the DP700, both the standa

Pagina 30

This chapter details the cable connections for the DP700.Connection DetailsImportant DetailsConnectionsYou can only use the DP700 with Newall Spherosy

Pagina 31

This chapter explains how to interpret the display and use the keypad.Display and KeypadUnderstanding The DisplayUnderstanding The KeypadAxis Selectio

Pagina 32

Setting Up The UnitNavigating Complete SetupHow to enter setup setupencoderusn 10Usn 5Sph 2GUntil display showsfuncssetupUnit then displayssetupcode?s

Pagina 33 - Trouble Shooting Guide

Setting Up The UnitNavigating Complete Setup (continued)setupfuncsonoffset functoolsset functaperset funcsummingset funcpcdset funclineset funcarcset

Pagina 34 - 023-81380-UK/2

Display Spherosyn™ 2G Microsyn™ 10 Microsyn™ 5µm mm in1 0.001 0.000052 0.002 0.00015 0.005 0.000210 0.01 0.000520 0.02 0.00150 0.05 0.002Setting Up

Comentarios a estos manuales

Sin comentarios